Speakman SEF-2001-8 Installation Guide

Browse online or download Installation Guide for Faucets Speakman SEF-2001-8. Speakman SEF-2001-8 Installation Guide User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 6
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
SEF-2001
SEF-2001-8
EYESAVER
Combination Faucet Spout
Turn off water supplies. Loosen and screw down the Spout Shank Nut (1).
Unscrew Tee Nut (2) from Spout Shank. Remove Shank Nut (1), mounting
hardware, and then remove Spout from counter top.
1
Using a Tube Cutter, cut the copper tubing between each End Body and
the Tee Assembly. Remove and discard remaining copper tube and
Capture Nuts from End Bodies. Remove COLD supply line from wall
stop and COLD End Body.
Crescent
Wrench
Flat Head
Screwdriver
Keep the EYESAVER
faucet spout looking new by
cleaning it periodically with a soft cloth. Avoid
abrasive cleaners, steel wool, and harsh chemicals
as these will dull the finish and void your warranty.
Cover your drain to prevent loss of parts. Always
wear eye protection.
The supply line for this unit shall provide an
uninterruptible supply of flushing fluid at a minimum
of 30 psi flowing pressure. If shut off valves are
installed in the supply line of the eyewash, provisions
shall be made to prevent unauthorized shut off.
ANSI Z358.1 requires that all emergency equipment
shall be tested weekly to verify proper operation and
inspected annually to assure conformance with
ANSI Z358.1 requirements. Be sure to read
instructions thoroughly before beginning installation.
Do not overtighten any connections or damage may
occur.
92-SEF-2001-R1
®
2
®
1
2
Tube
Cutter
Basin
Wrench
Page view 0
1 2 3 4 5 6

Summary of Contents

Page 1 - EYESAVER

SEF-2001SEF-2001-8EYESAVERCombination Faucet SpoutTurn off water supplies. Loosen and screw down the Spout Shank Nut (1).Unscrew Tee Nut (2) from Spou

Page 2

With Spout fully removed, verify diameter of hole in counter top is a minimum of 1-1/4”. Install mounting studs into base of Spout.From beneath count

Page 3

Retrieve supplied hose with a 3/8” fitting on one end, and a 1/2”fitting on the other. Connect 3/8” fitting end to the “F” port of theTee with check v

Page 4

Retrieve the two (2) remaining supplied hoses. Take the first hose andconnect one end to the “E” port of the Supply Tee with no checkvalves. Connect t

Page 5 - Eyewash Flow Data

psi bar gpm L/min in. cm.30 2.07 2.14 8.1 12 30.540 2.76 2.25 8.5 13 33.050 3.45 2.49 9.4 15 38.160 4.14 2.70 10.2 18 45.770 4.83 2.95 11.2 21 53.380

Page 6 - ROUGH-IN MEASUREMENTS

ROUGH-IN MEASUREMENTS 4-1/2" 19” (SEF-2001)17” (SEF-2001-8) (2 HOSES) 2-5/8" 2" MAX. DECK HEIGHT 2-1/4" 8" 12° 4-7/8&