92-3207-R1
SPEAKMAN COMPANY
S-2460 Installation, Maintenance & Operation Instructions
ADJUSTA-SPRAY ® SHOWERHEAD
DESCRIPTION
Polished chrome plated solid brass ADJUSTA-SPRAY wall mounted showerhead, 2” face. 60 spray channels at three
different angles to allow a full coverage shower. Drilled for but less mounting bolts. Water conserving pressure
compensating AUTOFLO® device reduces flow to 2.5 GPM/9.46LPM maximum to meet existing ANSI A112.18.1M
Standard. Vandal resistant standard. ½” NPTF back inlet.
SPECIFICATIONS OPTIONS
SUPPLY INLET: ½” NPTF
FLOW RATE: 2.5 GPM/9.46LPM MAXIMUM
FLOW CONTROL: VARIABLE
SHIPPING WEIGHT: 1.7 LBS.
INSTALLATION
Apply pipe thread tape in a clockwise direction to threads of supply nipple. Pipe joint compound may be used instead
of tape. Turning in a clockwise direction, thread the showerhead on to the supply nipple. Tighten & position with a
strap wrench or a pair of soft jaw pliers. Mark and drill holes for mounting screws (not provided). Note: If necessary,
remove showerhead and use proper screw anchor (3)(not provided). Turn the water supply on and check for leaks.
Tighten mounting screws (3).
OPERATION
To adjust the spray pattern of the showerhead, loosen the side set screw with a 3/32” hex wrench, then rotate the
spray face with a 3/16” hex wrench to the desired spray. Tighten the side set screw.
MAINTENANCE
ROUGH-IN MEASUREMENTS
AP – Anchor Plate Assembly with Mounting
Screws
The gleaming finish of your SPEAKMAN WATERSAVER® showerhead can be cleaned by using mild soap and
warm water. Dry immediately with a soft, clean cloth for best results. The flow control device limits water flow to 2.5
gallons per minute. The small orifices may become clogged with scale and other minerals found in potable water.
To clean the flow regulator, remove the showerhead from the wall, pull out the locking tab, dislodge the flow
re
g
ulator and clean as necessar
y
.
SPEAKMAN
®
PO Box 191 Wilmington, DE 19899 Phone: 800-537-2107 Fax: 800-977-2747
Visit us on the web at www.speakmancompany.com